Laserfiche WebLink
3. Remove the house and build a new one within the building envelope while (a) <br /> bringing the overall impervious coverage down to 20%or(b) bring overall <br /> impervious coverage down to 25%with stormwater plan. <br /> Proposal: <br /> The applicants have chosen to proceed with option number 2. <br /> Structure- The applicants have indicated that since the City will not allow them replace <br /> the existing non-conforming structure with a larger, non-conforming structure, they are <br /> willing renovate the existing structure and replace the existing basement. With the new <br /> footings and basement block walls, the structure's height would be increased by 2 feet. <br /> The applicants indicated that if they were to do this, the current floor plan of the house <br /> would have to be modified to allow the septic system to be installed on the south side of <br /> the house.The current footprint of the structure would not be modified. <br /> Impervious Coverage-The current impervious surface coverage of the lot is 32.8% while <br /> normally only 20% is allowed (the impervious coverage is able to be increased to 25% <br /> with a stormwater management plan). The applicants have submitted a plan to remove <br /> 926 sq. ft. of bituminous driveway area and install stormwater retention ponds on the <br /> north and south sides of the property. They are also proposing to remove 587 sq. ft. of <br /> pavers and sidewalk area, some of which is within the shore impact zone. The applicants <br /> are also proposing the remove 420 sq. ft. of gravel parking and a 188 sq. ft. deck on the <br /> lakeside (within lake setback) of the existing cabin. If the proposed plan is implemented <br /> in full,the total impervious surface coverage of the property would be 24.7%. <br /> Sewer System- The property currently contains a non-conforming sewer system. The <br /> property owners are seeking a variance to allow two new tanks to be installed within the <br /> 75 ft. OHW setback. The proposed tank that would be closest to the lake would be 50 ft <br /> from the OHW while the other would be installed directly to the east. The drainfield for <br /> the proposed system would encroach approximately 4 feet into the sideyeard setback and <br /> approximately 3 feet into the road right-of-way setback. <br /> Applicable Regulations: The purpose and intent of the Shoreline Residential district <br /> is to provide a zoning classification for riparian residential development. The zone may <br /> or may not be served by sewer and water, depending on availability(Section 17-5.8) <br /> Section 17-5.8 Applicable Shoreline Residential Lot Size&Dimension Requirements: <br /> GD Riparian Onlv <br /> Setback, right-of-way,local streets—feet, 10 <br /> minimum <br /> Setback, OHW—feet, minimum 75 <br /> Setback, side—feet,minimum 10 <br /> Impervious coverage—maximum 20% <br /> Building height-feet, maximum 25 <br /> ISTS setback from OHW—feet, minimum 75 <br /> Pequot Lakes Staff Report 4(a)-2 <br /> Novmeber 18,2010 <br />