My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
08 - Water/Wastewater Monthly Report
Laserfiche
>
City Council (Permanent)
>
Agenda Packets (Permanent)
>
2008
>
04-01-2008 Council Meeting
>
08 - Water/Wastewater Monthly Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2014 2:46:17 PM
Creation date
9/19/2014 2:46:15 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Police a City of Pequot City Hall <br /> 218-568-8111 r ' Lakes 218-568-5222 <br /> Fax 218-568-5647 1. Fax 218-568-5860 <br /> �p1pd @pequotlakes-mn.gov = 4638 County Road 11 cityhall @pequotlakes-mn.gov <br /> Pequot Lakes,MN 56472 <br /> www.pequotlakes-mn.gov <br /> Mayor/City Council/City Clerk <br /> Pequot Lakes, MN <br /> Water/Wastewater Report <br /> March 2008 <br /> POTABLE DRINKING WATER <br /> Facilities Performance: <br /> Average daily gallons pumped: 106,000 gallons <br /> Maximum daily gallons pumped: 134,000 gallons <br /> Minimum daily gallons pumped: 63,000 gallons <br /> Total monthly gallons pumped: 2,648,000 gallons (as of the 25th) <br /> Average daily chlorine concentration: .31 mg/1 <br /> Required chlorine concentration: .2 to .5 mg/1 <br /> Average daily fluoride concentration: 1.3 mg/1 <br /> Required fluoride concentration: 0.9 mg/1 to 1.5 mg/1 <br /> Treatment Chemicals Used for the Month: 10.7 gals Fluoride <br /> 21.0 lbs Chlorine <br /> II. Operations and Maintenance: <br /> • The MN Department of Health Monthly Fluoridation Report was completed and <br /> submitted. <br /> • Noted that one of two air compressors was not operating and had Moon Electric <br /> evaluate the cause. At first, he felt that it was on the air pump itself, but after running <br /> some troubleshooting on the air compressor in question, it was discovered that indeed it <br /> was an electrical issue. After isolating the compressor from service, it was determined <br /> that the starter contacts for the motor were the cause, and a new starter has been <br /> ordered. It appears that this compressor hasn't run for a while. <br /> • On the 4th, the two backflow preventing devices were serviced. This required re-build <br /> kits for each device and will be annually serviced and inspected for proper operation per <br /> requirement of the M.D.H. <br /> • Determined where the water plant filtration media level is at, since annually this should <br /> be checked to assure that the filter is optimizing in performance. Some loss of media is <br /> normal and since the start date of the plant, approximately 2"has been lost. <br />
The URL can be used to link to this page
Your browser does not support the video tag.