Laserfiche WebLink
33• �1 of the lots may be developed with single family homes without <br /> requiring variances. <br /> 34•Survey standards: The preliminary plat was prepared by a licensed <br /> surveyor(Patrick A.Trottier-PI.S #4ioo2) and conforms to the standards <br /> in Minnesota Statutes. <br /> 35•The subject property is accessed via a 33'wide easement Document <br /> #A888164. <br /> 36.Street improvement standards: The proposed private drive will be <br /> constructed by the developer and maintained by the home owners <br /> association. There are no public streets proposed in the development. <br /> 3�.Sanitary provision standards: The development will be served by a cluster <br /> sewer system. The system will be installed by the developer at his e�ense. <br /> The system will be maintained by the developer/home owner's association. <br /> 38.Water supply standards: The development will be served by a cluster <br /> water system. The system will be installed by the developer at his expense. <br /> The system will be maintained by the developer/home owner's association. <br /> 39•Drainage/grading standards: The total proposed impervious surface <br /> coverage of the development is i7.5% (20%allowed). An engineered <br /> stormwater management plan has not been submitted by applicant. <br /> 40.Dedication to the Public Standards: Section i�-9.io requires a payment or <br /> dedication to the City a portion of land for public use. This planned unit <br /> development does not include any land dedicated for public use. <br /> And subject to the following Conditions: <br /> On the conditional use permit and preliminary plat: <br /> i. F.xcept as amended by these conditions, the development of the <br /> subdivision and planned unit development shall be in substantial <br /> conformance with the approved preliminary plat, site plan and elevations <br /> that govern the general location of lots, roadways, buffers, infiltration <br /> basins and improvements dated Apri18, 2oi9. <br /> 2. Prior to construction, excavation, grading or other terrain disturbance, <br /> final plans for all infrastructure (private roads, water system, etc.) and <br /> grading shall be submitted to and approved by the City Engineer. The <br /> improvements within the development shall be designed by a licensed <br /> engineer. <br /> 3. The 50-foot buffer around the perimeter of the planned unit development <br /> shall remain in a natural state in perpetuity, except for road access areas <br /> and SSTS components. The vegetation in the buffer shall not be altered <br /> except to create areas for SSTS tanks/drainfield(s) and road accesses. <br /> Structures may not be constructed in the buffer. <br /> 4. Lots 1- 15 may only be developed with single family homes. <br /> 5. Lot 16 (greenspace) may not contain any structures, except a well house <br /> that will not exceed 12o square feet in size. Vegetation located in Lot �6 <br /> shall substantially remain in a natural state. Vegetation may be removed <br /> from Lot 16 in order to construct trails, private roads, sewer system, and <br /> water system. Reference to these provisions shall be made in the <br /> development covenants. <br /> Council Report 4 <br /> May�,2oi9 <br />