4 On the Design Criteria for a Planned Unit Development <br /> 1. A vegetative buffer of at least 50 feet is proposed along the entire PUD site area. <br /> There are no units or impervious surfaces proposed within this buffer. The <br /> applicant has not indicated the type of vegetation within the buffer area other than <br /> what currently exists on the property. <br /> 2. The applicant proposes to preserve 71% of the property as open space, exceeding <br /> the minimum Ordinance requirement of 25%. <br /> 3. The common space requirements and limitations have been met except for <br /> requirement 6 which states that the developer must preserve common space with <br /> restrictive deed covenants, permanent easements, public dedication and <br /> acceptance, or other equally effective and permanent means. The applicant has <br /> not submitted draft covenants for the common space. <br /> 4. The applicant has not yet submitted a stormwater management plan and has only <br /> submitted a general erosion control plan at this time. These documents will be <br /> reviewed by the City to ensure that, when implemented, these plans will be <br /> adequate to prevent soil erosion, control stormwater runoff, and prevent other <br /> pollution of public waters during and after construction. <br /> 5. Lots 1 and 15 will continue to use an existing drainfield sites and sewage <br /> treatment systems serving those dwellings. All remaining units will use a <br /> common community drainfield. The applicant has indicated a primary and an <br /> alternate drainfield upon an area within Lot 16 that is likely to be suitable for such <br /> a purpose. All lots will be served by common community wells and the applicant <br /> has indicated the potential location of these wells on the survey submitted. <br /> 6. The applicant has not indicated an exterior lighting plan indicating type of <br /> `-- lighting to be used and lighting patterns. The Ordinance specifies that all exterior <br /> lighting shall be directed downward and not illuminate parcels adjacent to the <br /> PUD, either directly or indirectly. <br /> 7. The applicant has proposed seven continuous mooring spaces for the <br /> development, equal to the number of units allowed in the first tier. These spaces <br /> would be split between two docking systems on the western portion of the <br /> property. The docks will be accessed via the existing in-ground steps leading from <br /> the upper part of the property down the bluff to the lakeshore. The applicant has <br /> also indicated a future lift to be installed for lake access. <br /> 8. The applicant has submitted a proposed color scheme for the dwelling units <br /> indicating that the units will be dark red in color. <br /> subject to the following conditions: <br /> 1. Prior to the submission of a final plat application, the following shall occur: <br /> a. The applicant shall submit association documents to the City Attorney for <br /> review and approval. The documents shall address the following, at a <br /> minimum: <br /> i. Mechanisms for the maintenance of common areas. <br /> ii. Mechanism for the maintenance of open space areas. <br /> iii. Mechanism for the maintenance of the docking system and access <br /> to the lake. <br /> b. Revisions shall be made to the documents to the satisfaction of the City <br /> Planning Commission 10 <br /> April 20, 2006 <br />