28755 Hwy 371, Pequot Lakes, MN 56472 Page 14 of 27 <br /> Electrical <br /> DESCRIPTION OF ELECTRICAL <br /> Size of Electrical Service: •120/240 Volt Main Service-Service Size:200 Amp <br /> Service Drop: *Underground <br /> Service Entrance Conductors: *Aluminum <br /> Service Equipment& <br /> Main Disconnects: *Main Service Rating 200 Amps *Breakers <br /> *Located:Basement-Utility Room <br /> Service Grounding: *Copper *Water Pipe Connection <br /> Service Panel & <br /> Overcurrent Protection: *Panel Rating:200 Amp *Breakers <br /> *Located:Basement-Utility Room <br /> Distribution Wiring: *Copper •Not Visible <br /> Wiring Method: *Non-Metallic Cable"Romex" <br /> Switches& Receptacles: *Grounded <br /> Ground Fault Circuit Interrupters: *Exterior <br /> ELECTRICAL OBSERVATIONS <br /> Positive Attributes <br /> The size of the electrical service is sufficient for typical single family needs. All 3-prong outlets that were tested were <br /> appropriately grounded. <br /> RECOMMENDATIONS/OBSERVATIONS <br /> Outlets <br /> • Safety Issue,Repair: A ground fault circuit interrupter(GFCI)outlet on the exterior of the home did not respond <br /> correctly to testing during the inspection. This receptacle should be replaced. <br /> Discretionary Improvements <br /> The installation of ground fault circuit interrupter(GFCI)devices is advisable on garage,bathroom and some kitchen outlets. <br /> LIMITATIONS OF ELECTRICAL INSPECTION <br /> As we have discussed and as described in your inspection contract,this is a visual inspection limited in scope by(but not <br /> restricted to)the following conditions: <br /> • Electrical components concealed behind finished surfaces are not inspected. <br /> • Only a representative sampling of outlets and light fixtures were tested. <br /> • Furniture and/or storage restricted access to some electrical components which may not be inspected. <br /> • The inspection does not include remote control devices,alarm systems and components,low voltage wiring, systems, <br /> and components,ancillary wiring, systems,and other components which are not part of the primary electrical power <br /> distribution system. <br /> Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. <br /> This confidential report is prepared exclusively for Dan Helbling <br /> 0 2008 Gold Key Home Inspection Services,LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.