28755 Hwy 371, Pequot Lakes, MN 56472 Page 11 of 27 <br /> Plumbing <br /> DESCRIPTION OF PLUMBING <br /> Water Supply Source: *Private Water Supply <br /> Service Pipe to House: *Steel <br /> Main Water Valve Location: *Beside Water Heater <br /> Interior Supply Piping: •Copper *Not Visible <br /> Waste System: *Private Sewage System <br /> Drain,Waste, &Vent Piping: *Plastic *Steel*Cast Iron *Not Visible <br /> Water Heater: •Electric •Approximate Capacity(in gallons): 50 <br /> •Manufacturer:A O Smith •Serial Number:L04 7118770 <br /> Fuel Shut-Off Valves: *Natural Gas Main Valve At East Exterior <br /> Other Components: *Solid Waste Pump <br /> PLUMBING OBSERVATIONS <br /> Positive Attributes <br /> The water pressure supplied to the fixtures is reasonably good. A typical drop in flow was experienced when two fixtures <br /> were operated simultaneously. <br /> RECOMMENDATIONS/OBSERVATIONS <br /> Water Heater <br /> • Safety Issue,Repair: The discharge piping serving the Temperature and Pressure Relief(TPR)Valve for the water <br /> heater should terminate not less than 6 inches or more than 24 inches above the floor. <br /> `. Waste/Vent <br /> • Repair: Unsealed opening in the waste piping in the laundry room(@ main DWV)should be corrected. <br /> • Repair: It is suspected that the waste piping in the second floor bathroom(@ sink)is clogged/obstructed.Further <br /> review is needed. <br /> Fixtures <br /> • Repair: The toilet in the main bathroom is loose. <br /> LIMITATIONS OF PLUMBING INSPECTION <br /> As we have discussed and as described in your inspection contract,this is a visual inspection limited in scope by(but not <br /> restricted to)the following conditions: <br /> • Portions of the plumbing system concealed by finishes and/or storage(below sinks,etc.),below the structure,or beneath <br /> the ground surface are not inspected. <br /> • Water quantity and water quality are not tested unless explicitly contracted-for and discussed in this or a separate report. <br /> • Clothes washing machine connections are not inspected. <br /> • Interiors of flues or chimneys which are not readily accessible are not inspected. <br /> • Water conditioning systems, solar water heaters,fire and lawn sprinkler systems,and private waste disposal systems are <br /> not inspected unless explicitly contracted-for and discussed in this or a separate report. <br /> Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. <br /> This confidential report is prepared exclusively for Dan Helbling <br /> 0 2008 Gold Key Home Inspection Services,LLC <br />