Laserfiche WebLink
� <br /> /NSPECTOR SK/ <br /> Yf/r.1r IIJ�'f�lil)Ni <br /> September 23,Z020 <br /> Inspectar Ski Home Inspections <br /> 1108 Hillside Terrace <br /> Bismarck,ND 58501 <br /> TS Properties LLC <br /> �6 Tom Smith <br /> PO Box 49 <br /> Watford City,ND 58854 <br /> Dear Mr Smith, <br /> Please find below an assessment of the condition of the structure of your home located 1805 4th Ave NE in <br /> Watford City, NQ.The home is a single-wide manufactu�ed home certified on December 02,2005 by Destiny <br /> Industries in Georgia(data plate base cabinet next to sink)HUD labe)NTA1376093.You have asked me to assess <br /> the property accorcfing to a City Code Sedion 17-4.5 Building Standards for the following: <br /> Certification That the eledrical wiring meets state codes:The wiring in the home is built to 20U5 HUD <br /> standa�ds which met state code standards at that time.The electricity was in service at this�esidence during the <br /> inspection and tested satisfactory.The electrical panel is rated at 200 amps.The system is grounded.There are <br /> GFCI outlets where necessary at the time of manufacture.7t�ere are no broken switches or outlets.Recommend <br /> instatling updated smoke and CO detectors after transit. <br /> Certification that the plumbing meets state codes:The water was not in service during the inspection.The <br /> pl�mbing system was constructed using 2005 HUD standards and appeared unaltered.Slight water damage to <br /> wall adjacent to shower due to not closing shower curtain during use.Water heate�is a 40 gallon Richmond WH <br /> manufactured in 2018. <br /> An evaluation of the foundation adaptability and conditions:The home was set using an all steel foundation <br /> system,concrete blocks and wood wedges that meet the industry and HUD standards.See page 79 <br /> https://www.huduser.aov/aartal/�ublications/PD�/founda#ions �uide.ndf. The home will require the same <br /> system or frast free system as the state it is moving to directs,using supports per manufacturer's <br /> specifications.https:/�www.hami Itanhb.sorr►/ <br /> An evaluation of the roof condition:Class III architectura!shingles with gutters installed.Shingles are in their <br /> first b of serviceable life and with no material defects noted.Ventilation system is�idge venting. <br /> M evaluation of the structural integrity:The Home is structural sound with no noted material defeds in the <br /> frame,floor,walls or ceiling systems.Recommend evaluation after the home is moved to assess for damage that <br /> may have occur�ed in transit. <br /> Certification that all doors,windaws and siding are In acceptable condition:Windows and doors are in tact,no <br /> noticeable condensation between panes,or leaking seals noted,Slight trim damage around doors.Wlndows <br /> operate,but are in need of lubrication due to non-use.Doors swing and close,but these will require post move <br /> adjustment to work properly.There are some pieces of siding(most notably on the north side)that show hail <br />