Laserfiche WebLink
SEC. 21.301.07. EXTERIOR LIGHTING. <br /> (a) Purpose and intent. The City of Bloomington recognizes the health, safety, welfare, and aesthetic <br /> value of providing lighting standards in the community. This Section's provisions are intended to: <br /> (1) Promote the public health, safety, and general welfare; <br /> (2) Establish efficient and cost effective lighting requirements adequate for safety and security; <br /> (3) Reduce light pollution, light trespass, glare, and offensive light sources; <br /> (4) Provide an environmentally sensitive nighttime environment; <br /> (5) Discourage inappropriate, poorly designed or installed outdoor lighting by requiring quality lighting <br /> design, light fixture shielding, and maximum uniformity ratios; <br /> (6) Protect motor vehicle operators, pedestrians, and adjacent land uses from glare; and <br /> (7) Implement the City's Comprehensive Plan. <br /> (b) Lighting plan. Except for single and two-family dwellings, no exterior lighting may be installed prior to <br /> approval of a lighting plan by the Issuing Authority. Modifying approved lighting, including lamp or fixture <br /> substitution, requires Issuing Authority approval. All plans must be signed by a registered Electrical <br /> Engineer or a Lighting Certified (LC) professional certified by the National Council on Qualifications for <br /> the Lighting Professions. The lighting plan must include the following information and attachments: <br /> (1) Name of project, developer, property owner, and architecUdesigner(all applicable); <br /> (2) Date of initial plan preparation and all amendments; <br /> (3) Scale of plan (engineering scale only, at a scale of one (1) inch equals fifty (50)feet or less)with <br /> North point indication; <br /> (4) An accurate site plan indicating the location of property lines and all existing and proposed land <br /> improvements including but not limited to buildings, parking lots, aisles and driveways, streets, <br /> walkways and accessory structures; <br /> (5) The location and description of all existing over story landscaping unless an approved or proposed <br /> landscape plan is provided; <br /> (6) The location and height above grade of all proposed and existing exterior fixtures (includes <br /> decorative and all mounted lighting)on the property; <br /> (7) Control descriptions including hours of operation and type of controls(timer, motion sensor, time <br /> clock, etc.), the light fixtures to be controlled by each type, and control schedule; <br /> (8) Two separate photometric plans superimposed on a site plan (See Section 21.301.07(b)(5)), one <br /> plan with the initial at-grade foot-candle levels and the other the maintained at-grade foot-candle <br /> levels. Photometric points must be on a grid ten feet by ten feet or less across the entire site and a <br /> minimum of ten feet or more beyond the lot or parcel property line. Each point must be to the <br /> nearest 0.1 foot-candle; <br /> (9) A luminaire schedule table indicating maximum to minimum uniformities for each specific use area <br /> such as parking and circulation areas, pedestrian areas, and other common public areas, the type <br /> of light source, light source wattage and initial light output lumens rating, color rendering index, <br /> color temperature and light loss factor of each lamp source; <br /> (10) Detailed information on each light fixture including copy of the manufacturers catalog information <br /> sheet and IESNA photometric distribution type, including any shielding information such as house <br /> side shields, internal, and/or external shields; and <br /> (11) Energy use calculations showing compliance with the Minnesota Energy Code, without <br /> exemptions. All parking lots regulated by this Section are considered public parking lots in the <br /> Minnesota State Energy Code. <br /> (c) Lighting standards. In addition to the following specific requirements, all exterior lighting must comply <br /> with the standards set forth in Section 21.301.07. <br /> (1) No person may install or operate any device with light levels other than as specified in this Section. <br /> (2) Luminaire. A complete lighting unit extending from a support structure, parallel to the ground, <br /> consisting of a light source and all necessary mechanical, electrical and decorative parts. The light <br /> source, lens and other components do not extend below the cutoff angle for the luminaire where a <br />